Fire Detection, Fire Fighting & Pump
Products

We provide reliable fire detection and fire fighting systems designed to protect lives and property. Our products include smoke detectors, alarm systems, sprinklers, and extinguishers that ensure fast response and effective fire prevention for buildings and industrial facilities.

BRAND HIGHLIGHT
  • NOHMI
  • Wilo

All Products

Filter by Category
Filter by Merk
Reset Filter
CSC004 | System Interface Unit

The SIU (System Interface Unit) is the optional device for the system. The SIU provides the system with the ability to establish communication between the System Monitoring Program (SMP) installed in a personal computer and FACPs on the network. The network is comprised of 64 nodes so that 1 set of SIU and SMP is able to communicate with a maximum of 63 FACPs. The SIU is comprised of two parts such as the AC/DC switching power supply part and the communication part. The AC/DC switching power supply part converts the AC power to the DC power, and supplies the 24 VDC power to the communication part for its operation. The communication part consists of a central microprocessor, Arcnet controller, and memory that allows it to communicate with other FACPs on the network. Using the optional Fiber-optic Interface Module (PCA-2707XA FIM or PCA-N3060-FIM2) together with SIU provides the system with the ability to use the fiber optic system for the network. The 5 VDC power for PCA-2707XA FIM or PCA-N3060-FIM2 is also supplied from the SIU to the PCA-2707XA FIM or PCA-N3060-FIM2 when required.

FRRU004-GSCU | Gas Suppression Control Unit

The FRRU004-GSCU module is used to control gas suppression systems. The FRRU004-GSCU is capable of discharging the gas either by
automatic or manual. The FRRU004-GSCU monitors manual release switch and abort switch status, counts down to gas discharge, operates
output devices, and indicates the gas discharge. The FRRU004-GSCU has the changeover switch which selects Auto & Manual or Manual Only.
The FRRU004-GSCU continuously supervises the wiring connected to the terminals NAC1, NAC2 and DI for open or short circuits and presence
of 24VDC

FRRJ001A-Y-S FRRJ001-Y-4S | Wet Output Type

The Addressable Modules, Wet Output Type, 1 Address with 4 Circuits, 4 Addresses with 16 Circuits provide programmable sources of power to
control and operate output devices including notification appliances and releasing devices.
The FRRJ001A-Y-S has 1 address with 4 circuits per unit, so that 4 different circuits can be controlled under 1 address number. The
FRRJ001-Y-4S has 4 addresses with 16 circuits per unit, so that 4 different circuits can be controlled under 1 address number. Each circuit
of the FRRJ001A-Y-S and the FRRJ001-Y4S has the functionality to receive a return signal from the connected device, which is used to
confirm the activation of the connected device. These circuits can also be used to have input signals
The FRRJ001A-Y-S and the FRRJ001-Y-4S are slim units and can be installed easily

FDHU003-D-X | Rate-of-Rise / Fixed Temperature Heat Detector

The combination Rate-of-Rise/Fixed Temperature Heat Detector (FDHU003-D-X) is an Analog/Addressable combination temperature heat of Integlex Multicrest series.

CNI016N | System Monitoring Program

The SMP is software to be installed in a personal computer. By connecting to the FACP network via the System Interface Unit (SIU), the SMP provides the system with an ability to monitor the FACPs on the network, displays events currently occurring, and controls systems. The SMP consists of three modes such as the Design Mode, Run Mode, and Remote Mode. In the Design Mode, registered device symbols are arranged on floor plans that come from DXF or BMP formatted data files, and the arranged symbols are given their addresses that are corresponded to addresses in FACPs. The SMP can utilize the configuration data of FACP to prepare the symbols of addressable devices. By reading the configuration data of FACP into itself, the SMP
automatically creates a list of device symbols that should be configured on the floor plans. A node number and a group number are assigned for each SMP for its identification on the network

FRRJ001A-Y-SS FRRJ001-Y-2SS FRRJ001-Y-4SD | Dry Contact Type

The Addressable Modules, Dry Output Type, 1 Address with 4 Circuits, 2 Addresses with 8 Circuits,4 Addresses with 16 Circuits are the relay
contact modules that are programed to activate when mapped devices are activated.
The FRRJ001A-Y-SS has 1 address with 4 circuits/contacts per unit, so that 4 different circuits/contacts can be controlled under 1 address number.
The FRRJ001-Y-2SS has 2 addresses with 8 circuits/contacts per unit, so that 4 different circuits/contacts can be controlled under 1 address number.
The FRRJ001A-Y-SS and the FRRJ001-Y-2SS also have 4 input cirsuits and 8 input cirsuits respectively which can be used to have return signals from
connected devices for activation confirmation of the connected devices, or can be used to have input signals from normally-open contact devices.
The FRRJ001-Y-4SD has 4 addresses with 16 circuits/contacts per unit, so that 4 different circuits/contacts can be controlled under 1 address number.
The FRRJ001A-Y-SS, the FRRJ001-Y-2SS and the FRRJ001-Y-4SD are slim units, and they can be installed easily

N3060

The N3060 Fire Alarm Control Panel employs a TFT 10.4 inch large color touch screen interface which provides faster & easier system operation and displays a range of comprehensive system information. The N3060 FACP is capable of having a maximum of 12 loops that supports up to 3,060 addressable devices.

FRRJ001A-Y-G | Gas Detector Module

The Addressable Module for Gas Detector supervises the compatible gas detectors connected to its circuits. The FRRJ001A-Y-G has 4 circuits
per unit, so that 4 different circuits can be controlled under 1 address number. The FRRJ001A-Y-G detects alarm conditions and report to the Fire
Alarm Control Panel (FACP) by supervising the voltage output of connected gas detectors.
The FRRJ001A-Y-G is a slim unit, and it can be installed easily

Integlex Multicrest N765

The Integlex Multicrest N765 is a UL listed expandable and intelligent addressable fire alarm system.
The N765 is designed to fit small space. The N765 is suitable for the gas suppression control with a simple configuration tool and module. The N765 is capable of having a maximum of 3 loops that support up to 765 addressable devices.